Energy Performance Certificate

24, Ynyswen, Penycae, SA9 1YS

EPC Report

Energy rating

Current: 66 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 55 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 79 Potential: 79
Field Value
LMK KEY 0600-2859-7772-9507-3665
ADDRESS1 24, Ynyswen
ADDRESS2 Penycae
ADDRESS3
POSTCODE SA9 1YS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-03-01
LOCAL AUTHORITY W06000023
CONSTITUENCY W07000085
COUNTY
LODGEMENT DATE 2013-03-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 187
ENERGY CONSUMPTION POTENTIAL 63
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 61
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 597
HEATING COST POTENTIAL 477
HOT WATER COST CURRENT 195
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24, Ynyswen, Penycae
LOCAL AUTHORITY LABEL Powys
CONSTITUENCY LABEL Brecon, Radnor and Cwm Tawe
POSTTOWN SWANSEA
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-03-12 20:40:19
TENURE Rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10011789981
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew