Energy Performance Certificate

East Coach House, DT11 8DB

EPC Report

Energy rating

Current: 86 B | Potential: 104 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 104 A Potential: 104 A

Environmental impact (CO₂)

Current: 98 | Potential: 103
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 98 Current: 98 103 Potential: 103
Field Value
LMK KEY 0589-3010-9308-5175-1204
ADDRESS1 East Coach House
ADDRESS2
ADDRESS3
POSTCODE DT11 8DB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 86
POTENTIAL ENERGY EFFICIENCY 104
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-08-08
LOCAL AUTHORITY E06000059
CONSTITUENCY E14001388
COUNTY
LODGEMENT DATE 2025-08-08
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 98
ENVIRONMENT IMPACT POTENTIAL 103
ENERGY CONSUMPTION CURRENT 50
ENERGY CONSUMPTION POTENTIAL 13
CO2 EMISSIONS CURRENT 0.3
CO2 EMISS CURR PER FLOOR AREA 1.6
CO2 EMISSIONS POTENTIAL -0.5
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 94
HEATING COST CURRENT 392
HEATING COST POTENTIAL 392
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 193
TOTAL FLOOR AREA 166
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.16 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL
WIND TURBINE COUNT
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.94
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS East Coach House
LOCAL AUTHORITY LABEL Dorset
CONSTITUENCY LABEL North Dorset
POSTTOWN Blandford Forum
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2025-08-08 19:51:43
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 30
UPRN 10097077473
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew