Energy Performance Certificate

79a Bell Hill, GU32 2DX

EPC Report

Energy rating

Current: 71 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 64 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 76 Potential: 76
Field Value
LMK KEY 0581-3035-4207-6734-7204
ADDRESS1 79a Bell Hill
ADDRESS2
ADDRESS3
POSTCODE GU32 2DX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-03-08
LOCAL AUTHORITY E07000085
CONSTITUENCY E14001214
COUNTY
LODGEMENT DATE 2024-03-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 174
ENERGY CONSUMPTION POTENTIAL 106
CO2 EMISSIONS CURRENT 6.2
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 187
LIGHTING COST POTENTIAL 190
HEATING COST CURRENT 1936
HEATING COST POTENTIAL 1557
HOT WATER COST CURRENT 258
HOT WATER COST POTENTIAL 161
TOTAL FLOOR AREA 201
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 20
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 79a Bell Hill
LOCAL AUTHORITY LABEL East Hampshire
CONSTITUENCY LABEL East Hampshire
POSTTOWN PETERSFIELD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-03-11 08:20:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100060280269
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew