Energy Performance Certificate

5, High Street, Nelson, CF46 6EU

EPC Report

Energy rating

Current: 14 G | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 14 G Current: 14 G 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 27 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 86 Potential: 86
Field Value
LMK KEY 0578-1014-7262-3525-8920
ADDRESS1 5, High Street
ADDRESS2 Nelson
ADDRESS3
POSTCODE CF46 6EU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 14
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-02-03
LOCAL AUTHORITY W06000018
CONSTITUENCY W07000088
COUNTY
LODGEMENT DATE 2015-02-10
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 629
ENERGY CONSUMPTION POTENTIAL 89
CO2 EMISSIONS CURRENT 9.0
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 107
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1946
HEATING COST POTENTIAL 459
HOT WATER COST CURRENT 511
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 85
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 80
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, High Street, Nelson
LOCAL AUTHORITY LABEL Caerphilly
CONSTITUENCY LABEL Caerphilly
POSTTOWN TREHARRIS
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-02-10 14:22:20
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 1
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 43007435
UPRN SOURCE Energy Assessor
REPORT TYPE 2