Energy Performance Certificate

10, Talbot Street, Chipping, PR3 2QE

EPC Report

Energy rating

Current: 40 E | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 46 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 78 Potential: 78
Field Value
LMK KEY 0576-2837-6594-9628-4711
ADDRESS1 10, Talbot Street
ADDRESS2 Chipping
ADDRESS3
POSTCODE PR3 2QE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-01-23
LOCAL AUTHORITY E07000124
CONSTITUENCY E14001443
COUNTY
LODGEMENT DATE 2018-01-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 417
ENERGY CONSUMPTION POTENTIAL 157
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 897
HEATING COST POTENTIAL 265
HOT WATER COST CURRENT 310
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 59
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10, Talbot Street, Chipping
LOCAL AUTHORITY LABEL Ribble Valley
CONSTITUENCY LABEL Ribble Valley
POSTTOWN PRESTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-01-24 11:40:47
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100010593850
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000002
Address display
Nation ew