Energy Performance Certificate

1, Langaller Close, Bovey Tracey, TQ13 9EB

EPC Report

Energy rating

Current: 55 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 49 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 72 Potential: 72
Field Value
LMK KEY 0568-8019-7264-5778-2940
ADDRESS1 1, Langaller Close
ADDRESS2 Bovey Tracey
ADDRESS3
POSTCODE TQ13 9EB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-04-06
LOCAL AUTHORITY E07000045
CONSTITUENCY E14001155
COUNTY
LODGEMENT DATE 2018-04-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 286
ENERGY CONSUMPTION POTENTIAL 138
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 120
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 899
HEATING COST POTENTIAL 725
HOT WATER COST CURRENT 248
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 112
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 91
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 31
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Warm air, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 31% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Langaller Close, Bovey Tracey
LOCAL AUTHORITY LABEL Teignbridge
CONSTITUENCY LABEL Central Devon
POSTTOWN NEWTON ABBOT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2018-04-08 20:09:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100040325418
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew