Energy Performance Certificate

56, Wasnidge Walk, NG3 1LD

EPC Report

Energy rating

Current: 68 D | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 98 | Potential: 98
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 98 Current: 98 98 Potential: 98
Field Value
LMK KEY 0566-2847-6081-2000-8325
ADDRESS1 56, Wasnidge Walk
ADDRESS2
ADDRESS3
POSTCODE NG3 1LD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2020-08-03
LOCAL AUTHORITY E06000018
CONSTITUENCY E14001410
COUNTY
LODGEMENT DATE 2020-08-03
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 98
ENVIRONMENT IMPACT POTENTIAL 98
ENERGY CONSUMPTION CURRENT 14
ENERGY CONSUMPTION POTENTIAL 14
CO2 EMISSIONS CURRENT 0.1
CO2 EMISS CURR PER FLOOR AREA 2
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 45
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 299
HEATING COST POTENTIAL 299
HOT WATER COST CURRENT 110
HOT WATER COST POTENTIAL 110
TOTAL FLOOR AREA 51
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Flat rate charging, programmer and TRVs
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 56, Wasnidge Walk
LOCAL AUTHORITY LABEL Nottingham
CONSTITUENCY LABEL Nottingham East
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2020-08-03 15:50:40
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 200001397129
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000004
Address display
Nation ew