Energy Performance Certificate

2, Coronation Road, Garnant, SA18 1LY

EPC Report

Energy rating

Current: 38 F | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 31 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 79 Potential: 79
Field Value
LMK KEY 0558-1005-7232-0847-8904
ADDRESS1 2, Coronation Road
ADDRESS2 Garnant
ADDRESS3
POSTCODE SA18 1LY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2013-02-05
LOCAL AUTHORITY W06000010
CONSTITUENCY W07000087
COUNTY
LODGEMENT DATE 2013-02-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 334
ENERGY CONSUMPTION POTENTIAL 71
CO2 EMISSIONS CURRENT 8.6
CO2 EMISS CURR PER FLOOR AREA 80
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 102
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 1452
HEATING COST POTENTIAL 469
HOT WATER COST CURRENT 225
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 107
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Coronation Road, Garnant
LOCAL AUTHORITY LABEL Carmarthenshire
CONSTITUENCY LABEL Caerfyrddin
POSTTOWN AMMANFORD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-02-05 17:54:21
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10004861485
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew