Energy Performance Certificate

13 Wildernesse House, Wildernesse Avenue, TN15 0EA

EPC Report

Energy rating

Current: 54 E | Potential: 54 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 54 E Potential: 54 E

Environmental impact (CO₂)

Current: 51 | Potential: 51
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 51 Potential: 51
Field Value
LMK KEY 0552-3841-7218-9093-7535
ADDRESS1 13 Wildernesse House
ADDRESS2 Wildernesse Avenue
ADDRESS3
POSTCODE TN15 0EA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 54
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-09-19
LOCAL AUTHORITY E07000111
CONSTITUENCY E14001465
COUNTY
LODGEMENT DATE 2017-09-19
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 51
ENERGY CONSUMPTION CURRENT 276
ENERGY CONSUMPTION POTENTIAL 276
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 6.6
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 78
HEATING COST CURRENT 1393
HEATING COST POTENTIAL 1393
HOT WATER COST CURRENT 137
HOT WATER COST POTENTIAL 137
TOTAL FLOOR AREA 137
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, TRVs
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.55 W/m²K
FLOOR ENERGY EFF Poor
FLOOR ENV EFF Poor
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Average thermal transmittance 0.86 W/m²K
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.19 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 13 Wildernesse House, Wildernesse Avenue
LOCAL AUTHORITY LABEL Sevenoaks
CONSTITUENCY LABEL Sevenoaks
POSTTOWN SEVENOAKS
CONSTRUCTION AGE BAND 2017
LODGEMENT DATETIME 2017-09-19 11:25:11
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10013775884
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2017.csv
COUNTRY England
REGION E12000008
Address display
Nation ew