Energy Performance Certificate

101, Cotmer Road, NR33 9PT

EPC Report

Energy rating

Current: 40 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 34 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 79 Potential: 79
Field Value
LMK KEY 0548-1934-6252-7284-6960
ADDRESS1 101, Cotmer Road
ADDRESS2
ADDRESS3
POSTCODE NR33 9PT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-12-04
LOCAL AUTHORITY E07000244
CONSTITUENCY E14001344
COUNTY
LODGEMENT DATE 2014-12-04
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 341
ENERGY CONSUMPTION POTENTIAL 94
CO2 EMISSIONS CURRENT 14
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 182
LIGHTING COST POTENTIAL 91
HEATING COST CURRENT 2420
HEATING COST POTENTIAL 855
HOT WATER COST CURRENT 367
HOT WATER COST POTENTIAL 177
TOTAL FLOOR AREA 209
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 12 mm loft insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 101, Cotmer Road
LOCAL AUTHORITY LABEL East Suffolk
CONSTITUENCY LABEL Lowestoft
POSTTOWN LOWESTOFT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-12-04 22:55:32
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100091164270
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display