Energy Performance Certificate

3, Orton Park, SA63 4WA

EPC Report

Energy rating

Current: 82 B | Potential: 112 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 112 A Potential: 112 A

Environmental impact (CO₂)

Current: 79 | Potential: 107
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 107 Potential: 107
Field Value
LMK KEY 0545-3868-7389-9506-1025
ADDRESS1 3, Orton Park
ADDRESS2
ADDRESS3
POSTCODE SA63 4WA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 112
PROPERTY TYPE House
BUILT FORM
INSPECTION DATE 2016-08-08
LOCAL AUTHORITY W06000009
CONSTITUENCY W07000100
COUNTY
LODGEMENT DATE 2016-08-08
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 107
ENERGY CONSUMPTION CURRENT 89
ENERGY CONSUMPTION POTENTIAL -83
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL -0.8
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 154
HEATING COST POTENTIAL 154
HOT WATER COST CURRENT 177
HOT WATER COST POTENTIAL 136
TOTAL FLOOR AREA 103
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.16 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.13 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Oil: heating oil
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 3, Orton Park
LOCAL AUTHORITY LABEL Pembrokeshire
CONSTITUENCY LABEL Mid and South Pembrokeshire
POSTTOWN CLARBESTON ROAD
CONSTRUCTION AGE BAND 2016
LODGEMENT DATETIME 2016-08-08 12:21:11
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10091644155
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display