Energy Performance Certificate

118, Roker Avenue, SR6 0HW

EPC Report

Energy rating

Current: 61 D | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 52 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 59 Potential: 59
Field Value
LMK KEY 0545-2820-7993-9176-1745
ADDRESS1 118, Roker Avenue
ADDRESS2
ADDRESS3
POSTCODE SR6 0HW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-01-30
LOCAL AUTHORITY E08000024
CONSTITUENCY E14001531
COUNTY
LODGEMENT DATE 2016-01-31
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 258
ENERGY CONSUMPTION POTENTIAL 212
CO2 EMISSIONS CURRENT 8.6
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 7.1
LIGHTING COST CURRENT 164
LIGHTING COST POTENTIAL 91
HEATING COST CURRENT 1596
HEATING COST POTENTIAL 1533
HOT WATER COST CURRENT 121
HOT WATER COST POTENTIAL 121
TOTAL FLOOR AREA 190
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 118, Roker Avenue
LOCAL AUTHORITY LABEL Sunderland
CONSTITUENCY LABEL Sunderland Central
POSTTOWN SUNDERLAND
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-01-31 18:28:56
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 45078845
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000001
Address display
Nation ew