Energy Performance Certificate

Flat 2 42 Bulmershe Road, RG1 5RJ

EPC Report

Energy rating

Current: 63 D | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 64 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 78 Potential: 78
Field Value
LMK KEY 0540-2155-8080-2529-1071
ADDRESS1 Flat 2 42 Bulmershe Road
ADDRESS2
ADDRESS3
POSTCODE RG1 5RJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-08-25
LOCAL AUTHORITY E06000038
CONSTITUENCY E14001438
COUNTY
LODGEMENT DATE 2021-09-22
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 316
ENERGY CONSUMPTION POTENTIAL 195
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 34
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 425
HEATING COST POTENTIAL 264
HOT WATER COST CURRENT 67
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 36
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 2 42 Bulmershe Road
LOCAL AUTHORITY LABEL Reading
CONSTITUENCY LABEL Reading Central
POSTTOWN Reading
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-09-22 13:14:18
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 310040035
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew