Energy Performance Certificate

39 GRANGE AVENUE, BINLEY, COVENTRY, CV3 2ED

EPC Report

Energy rating

Current: 47 E | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 44 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 55 Potential: 55
Field Value
LMK KEY 0532-1007-3304-5369-0204
ADDRESS1 39 GRANGE AVENUE
ADDRESS2 BINLEY
ADDRESS3 COVENTRY
POSTCODE CV3 2ED
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-04-07
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001180
COUNTY
LODGEMENT DATE 2021-04-07
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 381
ENERGY CONSUMPTION POTENTIAL 288
CO2 EMISSIONS CURRENT 4.8
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 87
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 985
HEATING COST POTENTIAL 989
HOT WATER COST CURRENT 92
HOT WATER COST POTENTIAL 65
TOTAL FLOOR AREA 73
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 56
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 1.20 W/m²K
FLOOR ENERGY EFF Very Poor
FLOOR ENV EFF Very Poor
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 2.10 W/m²K
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.21 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 56% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 39 GRANGE AVENUE, BINLEY, COVENTRY
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry East
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND 2021
LODGEMENT DATETIME 2021-04-07 10:26:13
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100070653255
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew