Energy Performance Certificate

33, Burlington Close, W9 3LY

EPC Report

Energy rating

Current: 64 D | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 59 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 67 Potential: 67
Field Value
LMK KEY 0529-2832-7550-9294-9875
ADDRESS1 33, Burlington Close
ADDRESS2
ADDRESS3
POSTCODE W9 3LY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-05-12
LOCAL AUTHORITY E09000033
CONSTITUENCY E14001435
COUNTY
LODGEMENT DATE 2014-05-21
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 225
ENERGY CONSUMPTION POTENTIAL 185
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 644
HEATING COST POTENTIAL 533
HOT WATER COST CURRENT 126
HOT WATER COST POTENTIAL 126
TOTAL FLOOR AREA 88
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Flat rate charging, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, TRVs
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33, Burlington Close
LOCAL AUTHORITY LABEL Westminster
CONSTITUENCY LABEL Queen's Park and Maida Vale
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-05-21 14:06:10
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100022730651
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000007
Address display
Nation ew