Energy Performance Certificate

32, Sebastian Close, CV3 4DW

EPC Report

Energy rating

Current: 71 C | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 75 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 79 Potential: 79
Field Value
LMK KEY 0520-2804-7123-9124-7295
ADDRESS1 32, Sebastian Close
ADDRESS2
ADDRESS3
POSTCODE CV3 4DW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2014-02-24
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001182
COUNTY
LODGEMENT DATE 2014-02-24
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 177
ENERGY CONSUMPTION POTENTIAL 147
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 380
HEATING COST POTENTIAL 334
HOT WATER COST CURRENT 75
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 53
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32, Sebastian Close
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry South
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-02-24 20:41:07
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100070697124
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew