Energy Performance Certificate

32, Fleming Road, SO22 6EE

EPC Report

Energy rating

Current: 57 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 41 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 85 Potential: 85
Field Value
LMK KEY 0519-2810-7232-9577-3225
ADDRESS1 32, Fleming Road
ADDRESS2
ADDRESS3
POSTCODE SO22 6EE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-07-30
LOCAL AUTHORITY E07000094
CONSTITUENCY E14001587
COUNTY
LODGEMENT DATE 2013-07-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 373
ENERGY CONSUMPTION POTENTIAL 72
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 87
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 616
HEATING COST POTENTIAL 451
HOT WATER COST CURRENT 238
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 85
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 38
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 38% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32, Fleming Road
LOCAL AUTHORITY LABEL Winchester
CONSTITUENCY LABEL Winchester
POSTTOWN WINCHESTER
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-07-30 18:37:48
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100060602153
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display
Nation ew