Energy Performance Certificate

185, Lockwood Square, SE16 2HY

EPC Report

Energy rating

Current: 68 D | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 98 | Potential: 98
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 98 Current: 98 98 Potential: 98
Field Value
LMK KEY 0518-7017-7283-1326-9924
ADDRESS1 185, Lockwood Square
ADDRESS2
ADDRESS3
POSTCODE SE16 2HY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-07-09
LOCAL AUTHORITY E09000028
CONSTITUENCY E14001085
COUNTY
LODGEMENT DATE 2016-07-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 98
ENVIRONMENT IMPACT POTENTIAL 98
ENERGY CONSUMPTION CURRENT 383
ENERGY CONSUMPTION POTENTIAL 383
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 112
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 25
LIGHTING COST POTENTIAL 25
HEATING COST CURRENT 337
HEATING COST POTENTIAL 337
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 193
TOTAL FLOOR AREA 32
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Flat rate charging, room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH 0
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 185, Lockwood Square
LOCAL AUTHORITY LABEL Southwark
CONSTITUENCY LABEL Bermondsey and Old Southwark
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-07-12 22:45:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 200003401896
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew