Energy Performance Certificate

41, Denham Close, TN38 9RS

EPC Report

Energy rating

Current: 73 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 71 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 85 Potential: 85
Field Value
LMK KEY 0518-6038-6269-6791-7994
ADDRESS1 41, Denham Close
ADDRESS2
ADDRESS3
POSTCODE TN38 9RS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2019-01-09
LOCAL AUTHORITY E07000062
CONSTITUENCY E14001274
COUNTY
LODGEMENT DATE 2019-05-31
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 169
ENERGY CONSUMPTION POTENTIAL 68
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 403
HEATING COST POTENTIAL 373
HOT WATER COST CURRENT 124
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 86
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 41, Denham Close
LOCAL AUTHORITY LABEL Hastings
CONSTITUENCY LABEL Hastings and Rye
POSTTOWN ST. LEONARDS-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2019-05-31 15:38:00
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100060043972
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew