Energy Performance Certificate

5, Preston Road, SW20 0SS

EPC Report

Energy rating

Current: 53 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 46 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 68 Potential: 68
Field Value
LMK KEY 0505-2868-7147-9907-5201
ADDRESS1 5, Preston Road
ADDRESS2
ADDRESS3
POSTCODE SW20 0SS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-04-08
LOCAL AUTHORITY E09000024
CONSTITUENCY E14001586
COUNTY
LODGEMENT DATE 2013-04-13
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 254
ENERGY CONSUMPTION POTENTIAL 138
CO2 EMISSIONS CURRENT 8.7
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 123
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 1376
HEATING COST POTENTIAL 1008
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 177
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Preston Road
LOCAL AUTHORITY LABEL Merton
CONSTITUENCY LABEL Wimbledon
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2013-04-13 13:14:54
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 43
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 48057702
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000007
Address display
Nation ew