Energy Performance Certificate

2, Tudor Road, DN2 6EN

EPC Report

Energy rating

Current: 59 D | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 71 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 81 Potential: 81
Field Value
LMK KEY 0505-2848-7090-9397-5875
ADDRESS1 2, Tudor Road
ADDRESS2
ADDRESS3
POSTCODE DN2 6EN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2013-01-18
LOCAL AUTHORITY E08000017
CONSTITUENCY E14001198
COUNTY
LODGEMENT DATE 2013-01-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 277
ENERGY CONSUMPTION POTENTIAL 185
CO2 EMISSIONS CURRENT
CO2 EMISS CURR PER FLOOR AREA
CO2 EMISSIONS POTENTIAL
LIGHTING COST CURRENT 29
LIGHTING COST POTENTIAL 20
HEATING COST CURRENT 440
HEATING COST POTENTIAL 354
HOT WATER COST CURRENT 55
HOT WATER COST POTENTIAL 55
TOTAL FLOOR AREA 31
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Tudor Road
LOCAL AUTHORITY LABEL Doncaster
CONSTITUENCY LABEL Doncaster Central
POSTTOWN DONCASTER
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-01-21 10:07:23
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10006626292
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display