Energy Performance Certificate

74, Elms Road, SW4 9EW

EPC Report

Energy rating

Current: 48 E | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 42 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 70 Potential: 70
Field Value
LMK KEY 0501-2849-7190-9877-2581
ADDRESS1 74, Elms Road
ADDRESS2
ADDRESS3
POSTCODE SW4 9EW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-01-31
LOCAL AUTHORITY E09000022
CONSTITUENCY E14001175
COUNTY
LODGEMENT DATE 2013-02-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 275
ENERGY CONSUMPTION POTENTIAL 130
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 5.4
LIGHTING COST CURRENT 152
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 1871
HEATING COST POTENTIAL 1069
HOT WATER COST CURRENT 152
HOT WATER COST POTENTIAL 122
TOTAL FLOOR AREA 215
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 35
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 16
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas, Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 16% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.14
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 74, Elms Road
LOCAL AUTHORITY LABEL Lambeth
CONSTITUENCY LABEL Clapham and Brixton Hill
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-02-05 18:32:40
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 44
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100021837414
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000007
Address display
Nation ew