Energy Performance Certificate

25, Newtown, Hullavington, SN14 6EQ

EPC Report

Energy rating

Current: 21 F | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 24 | Potential: 101
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 Current: 24 101 Potential: 101
Field Value
LMK KEY 0500-2803-7532-9292-8285
ADDRESS1 25, Newtown
ADDRESS2 Hullavington
ADDRESS3
POSTCODE SN14 6EQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-07-17
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001482
COUNTY
LODGEMENT DATE 2012-07-17
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 24
ENVIRONMENT IMPACT POTENTIAL 101
ENERGY CONSUMPTION CURRENT 588
ENERGY CONSUMPTION POTENTIAL 159
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 117
CO2 EMISSIONS POTENTIAL -0.2
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 1109
HEATING COST POTENTIAL 502
HOT WATER COST CURRENT 246
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 56
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 13
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, anthracite
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 13% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL anthracite
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.13
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 25, Newtown, Hullavington
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL South Cotswolds
POSTTOWN CHIPPENHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-07-17 15:26:09
TENURE
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100121010996
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew