Energy Performance Certificate

11a Penrhyn Road, LL29 8LG

EPC Report

Energy rating

Current: 46 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 52 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 84 Potential: 84
Field Value
LMK KEY 0498-3080-7213-5600-8240
ADDRESS1 11a Penrhyn Road
ADDRESS2
ADDRESS3
POSTCODE LL29 8LG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-07-01
LOCAL AUTHORITY W06000003
CONSTITUENCY W07000095
COUNTY
LODGEMENT DATE 2020-07-01
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 384
ENERGY CONSUMPTION POTENTIAL 123
CO2 EMISSIONS CURRENT 3.4
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 669
HEATING COST POTENTIAL 180
HOT WATER COST CURRENT 474
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 52
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.95
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11a Penrhyn Road
LOCAL AUTHORITY LABEL Conwy
CONSTITUENCY LABEL Clwyd North
POSTTOWN COLWYN BAY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-07-01 17:00:19
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100100418011
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew