Energy Performance Certificate

21, Mount Street, OL12 6TE

EPC Report

Energy rating

Current: 52 E | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 48 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 92 Potential: 92
Field Value
LMK KEY 0494-2808-6435-9297-8015
ADDRESS1 21, Mount Street
ADDRESS2
ADDRESS3
POSTCODE OL12 6TE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-07-18
LOCAL AUTHORITY E08000005
CONSTITUENCY E14001286
COUNTY
LODGEMENT DATE 2013-07-18
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 329
ENERGY CONSUMPTION POTENTIAL 48
CO2 EMISSIONS CURRENT 4.5
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 590
HEATING COST POTENTIAL 312
HOT WATER COST CURRENT 339
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 71
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 21, Mount Street
LOCAL AUTHORITY LABEL Rochdale
CONSTITUENCY LABEL Heywood and Middleton North
POSTTOWN ROCHDALE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-07-18 17:37:19
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 23060131
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew