Energy Performance Certificate

Azia Beach, Harlyn Bay, PL28 8SB

EPC Report

Energy rating

Current: 48 E | Potential: 57 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 57 D Potential: 57 D

Environmental impact (CO₂)

Current: 53 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 63 Potential: 63
Field Value
LMK KEY 0488-7045-7214-6531-8990
ADDRESS1 Azia Beach
ADDRESS2 Harlyn Bay
ADDRESS3
POSTCODE PL28 8SB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 57
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-04-08
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001385
COUNTY
LODGEMENT DATE 2019-04-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 232
ENERGY CONSUMPTION POTENTIAL 169
CO2 EMISSIONS CURRENT 6.2
CO2 EMISS CURR PER FLOOR AREA 39
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 157
LIGHTING COST POTENTIAL 104
HEATING COST CURRENT 1646
HEATING COST POTENTIAL 1692
HOT WATER COST CURRENT 203
HOT WATER COST POTENTIAL 118
TOTAL FLOOR AREA 158
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Azia Beach, Harlyn Bay
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL North Cornwall
POSTTOWN PADSTOW
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2019-04-08 18:07:34
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 40
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10003291605
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew