Energy Performance Certificate

Tower View, Tower Road, Terrington St. Clement, PE34 4LP

EPC Report

Energy rating

Current: 48 E | Potential: 100 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 100 A Potential: 100 A

Environmental impact (CO₂)

Current: 40 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 90 Potential: 90
Field Value
LMK KEY 0488-0025-7267-2553-9920
ADDRESS1 Tower View
ADDRESS2 Tower Road
ADDRESS3 Terrington St. Clement
POSTCODE PE34 4LP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 100
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2017-03-08
LOCAL AUTHORITY E07000146
CONSTITUENCY E14001405
COUNTY
LODGEMENT DATE 2017-03-08
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 267
ENERGY CONSUMPTION POTENTIAL -34
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 693
HEATING COST POTENTIAL 417
HOT WATER COST CURRENT 146
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 87
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Tower View, Tower Road, Terrington St. Clement
LOCAL AUTHORITY LABEL King's Lynn and West Norfolk
CONSTITUENCY LABEL North West Norfolk
POSTTOWN KING'S LYNN
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2017-03-08 19:15:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100091358262
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew