Energy Performance Certificate

10 East Street, Holme-On-The-Wolds, HU17 7PT

EPC Report

Energy rating

Current: 59 D | Potential: 109 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 109 A Potential: 109 A

Environmental impact (CO₂)

Current: 63 | Potential: 108
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 108 Potential: 108
Field Value
LMK KEY 0484-3011-9202-2792-4204
ADDRESS1 10 East Street
ADDRESS2 Holme-On-The-Wolds
ADDRESS3
POSTCODE HU17 7PT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 109
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2022-02-08
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001087
COUNTY
LODGEMENT DATE 2022-02-08
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 108
ENERGY CONSUMPTION CURRENT 244
ENERGY CONSUMPTION POTENTIAL -57
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL -0.9
LIGHTING COST CURRENT 120
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 971
HEATING COST POTENTIAL 440
HOT WATER COST CURRENT 310
HOT WATER COST POTENTIAL 208
TOTAL FLOOR AREA 91
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 10
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 36
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 36% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 East Street, Holme-On-The-Wolds
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Beverley and Holderness
POSTTOWN BEVERLEY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-02-08 16:35:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100050003464
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000003
Address display
Nation ew