Energy Performance Certificate

36, Petch Street, TS18 1PD

EPC Report

Energy rating

Current: 53 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 39 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 60 Potential: 60
Field Value
LMK KEY 0482-2805-6696-9891-1781
ADDRESS1 36, Petch Street
ADDRESS2
ADDRESS3
POSTCODE TS18 1PD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Bungalow
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-01-15
LOCAL AUTHORITY E06000004
CONSTITUENCY E14001518
COUNTY
LODGEMENT DATE 2019-02-01
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 432
ENERGY CONSUMPTION POTENTIAL 258
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 4.2
LIGHTING COST CURRENT 150
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 1421
HEATING COST POTENTIAL 974
HOT WATER COST CURRENT 338
HOT WATER COST POTENTIAL 178
TOTAL FLOOR AREA 97
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 20
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 36, Petch Street
LOCAL AUTHORITY LABEL Stockton-on-Tees
CONSTITUENCY LABEL Stockton North
POSTTOWN STOCKTON-ON-TEES
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2019-02-01 14:05:35
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100110192327
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000001
Address display
Nation ew