Energy Performance Certificate

108, Edinburgh Drive, PE13 3LP

EPC Report

Energy rating

Current: 44 E | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 45 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 86 Potential: 86
Field Value
LMK KEY 0481-2833-6648-9094-2935
ADDRESS1 108, Edinburgh Drive
ADDRESS2
ADDRESS3
POSTCODE PE13 3LP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-04-17
LOCAL AUTHORITY E07000010
CONSTITUENCY E14001390
COUNTY
LODGEMENT DATE 2014-04-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 328
ENERGY CONSUMPTION POTENTIAL 70
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 97
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 1018
HEATING COST POTENTIAL 460
HOT WATER COST CURRENT 369
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 99
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 108, Edinburgh Drive
LOCAL AUTHORITY LABEL Fenland
CONSTITUENCY LABEL North East Cambridgeshire
POSTTOWN WISBECH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-04-19 13:47:27
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100090079515
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew