Energy Performance Certificate

259, Stuart Road, PL1 5LH

EPC Report

Energy rating

Current: 53 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 46 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 63 Potential: 63
Field Value
LMK KEY 0478-2866-6556-9292-3965
ADDRESS1 259, Stuart Road
ADDRESS2
ADDRESS3
POSTCODE PL1 5LH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-05-16
LOCAL AUTHORITY E06000026
CONSTITUENCY E14001427
COUNTY
LODGEMENT DATE 2012-05-17
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 229
ENERGY CONSUMPTION POTENTIAL 141
CO2 EMISSIONS CURRENT 9.2
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 5.8
LIGHTING COST CURRENT 149
LIGHTING COST POTENTIAL 80
HEATING COST CURRENT 1574
HEATING COST POTENTIAL 1191
HOT WATER COST CURRENT 53
HOT WATER COST POTENTIAL 53
TOTAL FLOOR AREA 208
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 95
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 13
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 13% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.08
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 259, Stuart Road
LOCAL AUTHORITY LABEL Plymouth
CONSTITUENCY LABEL Plymouth Sutton and Devonport
POSTTOWN PLYMOUTH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-05-17 06:12:53
TENURE
FIXED LIGHTING OUTLETS COUNT 23
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100040492160
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew