Energy Performance Certificate

202, Sea Front, PO11 9HR

EPC Report

Energy rating

Current: 67 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 61 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 74 Potential: 74
Field Value
LMK KEY 0475-2899-6975-9826-7165
ADDRESS1 202, Sea Front
ADDRESS2
ADDRESS3
POSTCODE PO11 9HR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-03-21
LOCAL AUTHORITY E07000090
CONSTITUENCY E14001275
COUNTY
LODGEMENT DATE 2016-04-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 166
ENERGY CONSUMPTION POTENTIAL 103
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 159
LIGHTING COST POTENTIAL 99
HEATING COST CURRENT 1371
HEATING COST POTENTIAL 1067
HOT WATER COST CURRENT 153
HOT WATER COST POTENTIAL 153
TOTAL FLOOR AREA 245
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 202, Sea Front
LOCAL AUTHORITY LABEL Havant
CONSTITUENCY LABEL Havant
POSTTOWN HAYLING ISLAND
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-04-06 09:41:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 102
LOW ENERGY FIXED LIGHT COUNT 41
UPRN 100060447097
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000008
Address display
Nation ew