Energy Performance Certificate

14, Knoll Park, TR1 1FF

EPC Report

Energy rating

Current: 70 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 56 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 65 Potential: 65
Field Value
LMK KEY 0473-2801-7166-2300-2885
ADDRESS1 14, Knoll Park
ADDRESS2
ADDRESS3
POSTCODE TR1 1FF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-06-09
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001554
COUNTY
LODGEMENT DATE 2020-06-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 160
ENERGY CONSUMPTION POTENTIAL 119
CO2 EMISSIONS CURRENT 7.7
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 6.0
LIGHTING COST CURRENT 118
LIGHTING COST POTENTIAL 118
HEATING COST CURRENT 1130
HEATING COST POTENTIAL 1015
HOT WATER COST CURRENT 165
HOT WATER COST POTENTIAL 165
TOTAL FLOOR AREA 230
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 350 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Knoll Park
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL Truro and Falmouth
POSTTOWN TRURO
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2020-06-11 16:38:14
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 100040045095
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000009
Address display
Nation ew