Energy Performance Certificate

9, Chapel Close, Unsworth, BL9 8DF

EPC Report

Energy rating

Current: 67 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 60 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 73 Potential: 73
Field Value
LMK KEY 0463-2841-7344-9221-4045
ADDRESS1 9, Chapel Close
ADDRESS2 Unsworth
ADDRESS3
POSTCODE BL9 8DF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-04-29
LOCAL AUTHORITY E08000002
CONSTITUENCY E14001145
COUNTY
LODGEMENT DATE 2019-04-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 223
ENERGY CONSUMPTION POTENTIAL 152
CO2 EMISSIONS CURRENT 6.3
CO2 EMISS CURR PER FLOOR AREA 39
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 139
LIGHTING COST POTENTIAL 91
HEATING COST CURRENT 1033
HEATING COST POTENTIAL 903
HOT WATER COST CURRENT 137
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 161
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 48
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 48% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, Chapel Close, Unsworth
LOCAL AUTHORITY LABEL Bury
CONSTITUENCY LABEL Bury South
POSTTOWN BURY
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2019-04-30 07:00:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 33
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 100010953885
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000002
Address display
Nation ew