Energy Performance Certificate

132 Birch Crescent, RM11 2NG

EPC Report

Energy rating

Current: 69 C | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 65 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 88 Potential: 88
Field Value
LMK KEY 0461-3036-0204-5514-7204
ADDRESS1 132 Birch Crescent
ADDRESS2
ADDRESS3
POSTCODE RM11 2NG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-04-06
LOCAL AUTHORITY E09000016
CONSTITUENCY E14001448
COUNTY
LODGEMENT DATE 2024-04-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 203
ENERGY CONSUMPTION POTENTIAL 58
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 111
LIGHTING COST POTENTIAL 111
HEATING COST CURRENT 963
HEATING COST POTENTIAL 634
HOT WATER COST CURRENT 134
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 82
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 132 Birch Crescent
LOCAL AUTHORITY LABEL Havering
CONSTITUENCY LABEL Romford
POSTTOWN HORNCHURCH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-04-06 16:53:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100021323812
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew