Energy Performance Certificate

Second Floor Flat, 22 Finborough Road, SW10 9EQ

EPC Report

Energy rating

Current: 48 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 53 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 85 Potential: 85
Field Value
LMK KEY 0457-2891-7185-9708-9515
ADDRESS1 Second Floor Flat
ADDRESS2 22 Finborough Road
ADDRESS3
POSTCODE SW10 9EQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-08-09
LOCAL AUTHORITY E09000020
CONSTITUENCY E14001160
COUNTY
LODGEMENT DATE 2018-08-14
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 574
ENERGY CONSUMPTION POTENTIAL 188
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 97
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 40
LIGHTING COST POTENTIAL 20
HEATING COST CURRENT 456
HEATING COST POTENTIAL 140
HOT WATER COST CURRENT 137
HOT WATER COST POTENTIAL 64
TOTAL FLOOR AREA 20
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.9
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Second Floor Flat, 22 Finborough Road
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Chelsea and Fulham
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-08-14 15:37:38
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 2
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 217031986
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew