Energy Performance Certificate

88 Gwelfor, Dunvant, SA2 7QJ

EPC Report

Energy rating

Current: 31 F | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 1 | Potential: 104
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 104 Potential: 104
Field Value
LMK KEY 0451-3036-5204-4014-9204
ADDRESS1 88 Gwelfor
ADDRESS2 Dunvant
ADDRESS3
POSTCODE SA2 7QJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-04-05
LOCAL AUTHORITY W06000011
CONSTITUENCY W07000097
COUNTY
LODGEMENT DATE 2024-04-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 104
ENERGY CONSUMPTION CURRENT 489
ENERGY CONSUMPTION POTENTIAL 73
CO2 EMISSIONS CURRENT 14
CO2 EMISS CURR PER FLOOR AREA 187
CO2 EMISSIONS POTENTIAL -0.5
LIGHTING COST CURRENT 127
LIGHTING COST POTENTIAL 128
HEATING COST CURRENT 2267
HEATING COST POTENTIAL 881
HOT WATER COST CURRENT 1134
HOT WATER COST POTENTIAL 189
TOTAL FLOOR AREA 77
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 10
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, coal
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 88 Gwelfor, Dunvant
LOCAL AUTHORITY LABEL Swansea
CONSTITUENCY LABEL Gower
POSTTOWN SWANSEA
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-04-12 09:35:41
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100100329907
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY Wales
REGION W99999999
Address display