Energy Performance Certificate

1, Elan Close, DY12 2PR

EPC Report

Energy rating

Current: 45 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 38 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 76 Potential: 76
Field Value
LMK KEY 0450-2893-7235-9298-0855
ADDRESS1 1, Elan Close
ADDRESS2
ADDRESS3
POSTCODE DY12 2PR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2018-07-17
LOCAL AUTHORITY E07000239
CONSTITUENCY E14001601
COUNTY
LODGEMENT DATE 2018-07-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 428
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 6.4
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 968
HEATING COST POTENTIAL 563
HOT WATER COST CURRENT 246
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 84
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Elan Close
LOCAL AUTHORITY LABEL Wyre Forest
CONSTITUENCY LABEL Wyre Forest
POSTTOWN BEWDLEY
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-07-18 10:49:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100120717986
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000005
Address display
Nation ew