Energy Performance Certificate

89, Hartington Street, ME4 5PJ

EPC Report

Energy rating

Current: 49 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 41 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 76 Potential: 76
Field Value
LMK KEY 0447-2887-6611-9701-4121
ADDRESS1 89, Hartington Street
ADDRESS2
ADDRESS3
POSTCODE ME4 5PJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2019-09-03
LOCAL AUTHORITY E06000035
CONSTITUENCY E14001157
COUNTY
LODGEMENT DATE 2019-09-03
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 354
ENERGY CONSUMPTION POTENTIAL 121
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 1087
HEATING COST POTENTIAL 582
HOT WATER COST CURRENT 150
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 105
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 73
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 73% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 89, Hartington Street
LOCAL AUTHORITY LABEL Medway
CONSTITUENCY LABEL Chatham and Aylesford
POSTTOWN CHATHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2019-09-03 23:49:51
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 44053654
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew