Energy Performance Certificate

FLAT 88, GALAXY BUILDING, 5 CREWS STREET, E14 3SP

EPC Report

Energy rating

Current: 73 C | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 73 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 Current: 73 73 Potential: 73
Field Value
LMK KEY 0439-4824-6000-0763-5222
ADDRESS1 FLAT 88
ADDRESS2 GALAXY BUILDING
ADDRESS3 5 CREWS STREET
POSTCODE E14 3SP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2021-04-27
LOCAL AUTHORITY E09000030
CONSTITUENCY E14001430
COUNTY
LODGEMENT DATE 2021-04-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 73
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 116
ENERGY CONSUMPTION POTENTIAL 114
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 4.9
LIGHTING COST CURRENT 180
LIGHTING COST POTENTIAL 132
HEATING COST CURRENT 1117
HEATING COST POTENTIAL 1131
HOT WATER COST CURRENT 207
HOT WATER COST POTENTIAL 207
TOTAL FLOOR AREA 255
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 63% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 15
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS FLAT 88, GALAXY BUILDING, 5 CREWS STREET
LOCAL AUTHORITY LABEL Tower Hamlets
CONSTITUENCY LABEL Poplar and Limehouse
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2021-04-27 19:30:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 43
LOW ENERGY FIXED LIGHT COUNT 27
UPRN 6153887
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew