Energy Performance Certificate

124, Sandhurst Road, SE6 1XD

EPC Report

Energy rating

Current: 67 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 63 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 86 Potential: 86
Field Value
LMK KEY 0438-4068-7258-3485-1934
ADDRESS1 124, Sandhurst Road
ADDRESS2
ADDRESS3
POSTCODE SE6 1XD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-08-07
LOCAL AUTHORITY E09000023
CONSTITUENCY E14001331
COUNTY
LODGEMENT DATE 2015-08-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 210
ENERGY CONSUMPTION POTENTIAL 60
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 510
HEATING COST POTENTIAL 355
HOT WATER COST CURRENT 109
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 78
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 124, Sandhurst Road
LOCAL AUTHORITY LABEL Lewisham
CONSTITUENCY LABEL Lewisham East
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-08-08 18:40:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100022001591
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew