Energy Performance Certificate

The Old Chapel, Foston-on-the-Wolds, YO25 8BJ

EPC Report

Energy rating

Current: 42 E | Potential: 52 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 52 E Potential: 52 E

Environmental impact (CO₂)

Current: 58 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 66 Potential: 66
Field Value
LMK KEY 0438-2853-7451-9805-9355
ADDRESS1 The Old Chapel
ADDRESS2 Foston-on-the-Wolds
ADDRESS3
POSTCODE YO25 8BJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 52
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-05-07
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001127
COUNTY
LODGEMENT DATE 2015-05-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 175
ENERGY CONSUMPTION POTENTIAL 134
CO2 EMISSIONS CURRENT 9.4
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 7.5
LIGHTING COST CURRENT 167
LIGHTING COST POTENTIAL 107
HEATING COST CURRENT 2845
HEATING COST POTENTIAL 2707
HOT WATER COST CURRENT 295
HOT WATER COST POTENTIAL 172
TOTAL FLOOR AREA 248
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, LPG
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL LPG (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.27
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Old Chapel, Foston-on-the-Wolds
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Bridlington and The Wolds
POSTTOWN DRIFFIELD
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2015-05-07 14:09:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 200000635969
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display