Energy Performance Certificate

10, Peter Street, Frocester, GL10 3TQ

EPC Report

Energy rating

Current: 52 E | Potential: 103 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 103 A Potential: 103 A

Environmental impact (CO₂)

Current: 51 | Potential: 101
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 101 Potential: 101
Field Value
LMK KEY 0436-2825-7829-9905-4155
ADDRESS1 10, Peter Street
ADDRESS2 Frocester
ADDRESS3
POSTCODE GL10 3TQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 103
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-02-05
LOCAL AUTHORITY E07000082
CONSTITUENCY E14001529
COUNTY
LODGEMENT DATE 2015-02-05
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 101
ENERGY CONSUMPTION CURRENT 357
ENERGY CONSUMPTION POTENTIAL -10
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL -0.3
LIGHTING COST CURRENT 99
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 904
HEATING COST POTENTIAL 569
HOT WATER COST CURRENT 105
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 76
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10, Peter Street, Frocester
LOCAL AUTHORITY LABEL Stroud
CONSTITUENCY LABEL Stroud
POSTTOWN STONEHOUSE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-02-05 12:38:07
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 200003102151
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew