Energy Performance Certificate

58, Scott Close, Kings Somborne, SO20 6NS

EPC Report

Energy rating

Current: 72 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 66 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 83 Potential: 83
Field Value
LMK KEY 0434-2868-7665-9995-4355
ADDRESS1 58, Scott Close
ADDRESS2 Kings Somborne
ADDRESS3
POSTCODE SO20 6NS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-06-18
LOCAL AUTHORITY E07000093
CONSTITUENCY E14001449
COUNTY
LODGEMENT DATE 2015-07-06
TRANSACTION TYPE Following Green Deal
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 133
ENERGY CONSUMPTION POTENTIAL 25
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 35
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 519
HEATING COST POTENTIAL 381
HOT WATER COST CURRENT 379
HOT WATER COST POTENTIAL 90
TOTAL FLOOR AREA 80
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 92
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 92% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 58, Scott Close, Kings Somborne
LOCAL AUTHORITY LABEL Test Valley
CONSTITUENCY LABEL Romsey and Southampton North
POSTTOWN STOCKBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-07-06 19:51:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100060584335
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew