Energy Performance Certificate

54 Cowleigh Road, WR14 1QD

EPC Report

Energy rating

Current: 37 F | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 34 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 67 Potential: 67
Field Value
LMK KEY 0433-2885-7589-9625-2375
ADDRESS1 54 Cowleigh Road
ADDRESS2
ADDRESS3
POSTCODE WR14 1QD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-08-25
LOCAL AUTHORITY E07000235
CONSTITUENCY E14001579
COUNTY
LODGEMENT DATE 2015-08-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 373
ENERGY CONSUMPTION POTENTIAL 167
CO2 EMISSIONS CURRENT 22
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 9.8
LIGHTING COST CURRENT 221
LIGHTING COST POTENTIAL 131
HEATING COST CURRENT 4723
HEATING COST POTENTIAL 2307
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 142
TOTAL FLOOR AREA 372
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 12
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas, Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 54 Cowleigh Road
LOCAL AUTHORITY LABEL Malvern Hills
CONSTITUENCY LABEL West Worcestershire
POSTTOWN MALVERN
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-08-28 11:11:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 37
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100120598759
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000005
Address display
Nation ew