Energy Performance Certificate

1, Homestead Road, S5 0NA

EPC Report

Energy rating

Current: 63 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 57 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 78 Potential: 78
Field Value
LMK KEY 0430-2829-7019-9205-3701
ADDRESS1 1, Homestead Road
ADDRESS2
ADDRESS3
POSTCODE S5 0NA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-09-01
LOCAL AUTHORITY E08000039
CONSTITUENCY E14001466
COUNTY
LODGEMENT DATE 2015-09-02
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 257
ENERGY CONSUMPTION POTENTIAL 128
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 874
HEATING COST POTENTIAL 639
HOT WATER COST CURRENT 117
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 108
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Homestead Road
LOCAL AUTHORITY LABEL Sheffield
CONSTITUENCY LABEL Sheffield Brightside and Hillsborough
POSTTOWN SHEFFIELD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-09-02 13:51:13
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100051000743
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew