Energy Performance Certificate

1, The Ridgeway, WS7 4SQ

EPC Report

Energy rating

Current: 45 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 42 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 81 Potential: 81
Field Value
LMK KEY 0427-2848-7956-9307-9111
ADDRESS1 1, The Ridgeway
ADDRESS2
ADDRESS3
POSTCODE WS7 4SQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2013-05-08
LOCAL AUTHORITY E07000194
CONSTITUENCY E14001335
COUNTY
LODGEMENT DATE 2014-06-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 404
ENERGY CONSUMPTION POTENTIAL 116
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 78
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 761
HEATING COST POTENTIAL 498
HOT WATER COST CURRENT 266
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 62
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, The Ridgeway
LOCAL AUTHORITY LABEL Lichfield
CONSTITUENCY LABEL Lichfield
POSTTOWN BURNTWOOD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-06-11 12:05:37
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200001159129
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew