Energy Performance Certificate

21, Manor Green, DL7 8BA

EPC Report

Energy rating

Current: 71 C | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 71 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 86 Potential: 86
Field Value
LMK KEY 0422-2873-7585-9224-0325
ADDRESS1 21, Manor Green
ADDRESS2
ADDRESS3
POSTCODE DL7 8BA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-08-27
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001444
COUNTY
LODGEMENT DATE 2014-08-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 175
ENERGY CONSUMPTION POTENTIAL 89
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 534
HEATING COST POTENTIAL 491
HOT WATER COST CURRENT 105
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 86
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 21, Manor Green
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Richmond and Northallerton
POSTTOWN NORTHALLERTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-08-28 12:42:51
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 200003297019
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000003
Address display
Nation ew