Energy Performance Certificate

Hill View, Carrs Green, Inskip, PR4 0TJ

EPC Report

Energy rating

Current: 45 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 35 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 55 Potential: 55
Field Value
LMK KEY 0422-2823-7555-9704-3595
ADDRESS1 Hill View
ADDRESS2 Carrs Green
ADDRESS3 Inskip
POSTCODE PR4 0TJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-05-07
LOCAL AUTHORITY E07000128
CONSTITUENCY E14001318
COUNTY
LODGEMENT DATE 2014-05-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 310
ENERGY CONSUMPTION POTENTIAL 174
CO2 EMISSIONS CURRENT 8.0
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL 4.9
LIGHTING COST CURRENT 119
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1357
HEATING COST POTENTIAL 1161
HOT WATER COST CURRENT 285
HOT WATER COST POTENTIAL 114
TOTAL FLOOR AREA 106
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Hill View, Carrs Green, Inskip
LOCAL AUTHORITY LABEL Wyre
CONSTITUENCY LABEL Lancaster and Wyre
POSTTOWN PRESTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-05-07 18:36:36
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10003512655
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew