Energy Performance Certificate

96, Hardy Mill Road, BL2 3PH

EPC Report

Energy rating

Current: 58 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 52 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 71 Potential: 71
Field Value
LMK KEY 0421-2844-7167-9194-1961
ADDRESS1 96, Hardy Mill Road
ADDRESS2
ADDRESS3
POSTCODE BL2 3PH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-06-14
LOCAL AUTHORITY E08000001
CONSTITUENCY E14001110
COUNTY
LODGEMENT DATE 2014-06-16
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 235
ENERGY CONSUMPTION POTENTIAL 138
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 4.2
LIGHTING COST CURRENT 136
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 1188
HEATING COST POTENTIAL 969
HOT WATER COST CURRENT 194
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 155
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), limited insulation (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 96, Hardy Mill Road
LOCAL AUTHORITY LABEL Bolton
CONSTITUENCY LABEL Bolton North East
POSTTOWN BOLTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-06-16 08:40:02
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100010884723
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew